Reinstall your 3 phases original plug and keep 3” of wire. Weld the 3 wires on RMSTATOR’s wires using the original color code. Use locking compound on bolts when you reinstall the stator to avoid future problems.




STATOR

Five wires

Five terminals

ALTERNATOR White Between each White 0.6 ohms ±20%

ALTERNATOR White to Ground O.L ON DISPLAY

PICK UP COIL Black to White 185 ohms ±20%